Record vital signs in the visit's medical-record form and review the latest measurements in My Panel. Values, units, dates and abnormal flags are available as structured observations.

Record measurements#

  1. Open the patient's visit in My Panel.
  2. Use Record vitals when offered, or open the relevant medical-record form.
  3. Enter the measured values in the units shown by the form and save.
  4. Review the saved record and the latest-vitals summary. Correct a mistaken entry through the source form.

Where the clinic requires vitals and your role can record them, My Panel offers a view of visits waiting for vitals. A visit may first need reception to select its clinician. Discharged visits are not open for normal intake edits.

Units and validation#

The supported vital types use their defined units, including mmHg for blood pressure, bpm for heart rate, percent for oxygen saturation, Celsius for temperature, kilograms for weight and centimetres for height. Do not assume a tenant setting converts Fahrenheit, pounds or other units automatically.

The system checks plausibility limits for recognised measurements and can reject values that appear to use the wrong unit. Passing that check only means a value is plausible; it is not a clinical assessment. Verify both the value and unit before saving.

Read the summary#

The encounter shows the latest observations by type, with recorded units and dates. A recent measurement may come from an earlier visit, so check its timestamp before using it as today's baseline.

Age-based reference interpretation is calculated when recognised vitals are read. It is separate from the observation's recorded abnormal flag. The current implementation does not expose a tenant-configurable age/sex reference-range page or individual-patient range overrides.

Trends and alerts#

The current summary is a latest-readings view, not a full time-series chart with export or side-by-side metric comparison. Review earlier medical-record forms when you need the observation history.

Abnormal indicators are visual information in the record. Do not rely on a critical measurement automatically sending a push notification, creating a task or escalating to a clinician. Follow the clinic's escalation process and document who was informed and what action was taken.

Patient home-device capture, Bluetooth imports and a patient-facing tablet vitals workflow are not established by this guide. Only use the capture methods actually enabled for your clinic.

How saved observations relate to the record#

Saved vital-sign form responses populate structured observations with the patient, optional session, type, value, unit and timestamp. The source form remains the editing surface; the observation-list API is read-only.