NABIDH is Dubai Health Authority's (DHA) Health Information Exchange. Every DHA-licensed clinic must send a standardised electronic message to NABIDH for each real clinical event — a patient registering, a result, a diagnosis, a discharge — so that any DHA facility treating that patient sees one shared, accurate record. This page is the plain-language map of how your clinic stays compliant automatically, and the few things a human must get right so it does.

Scope: NABIDH (Dubai / DHA) only. Abu Dhabi (Malaffi / DoH) and the federal Riayati layer are not wired in the software today and must be handled directly through the regulator portal. Everything in this module is about DHA Dubai.

Why this matters to you as a manager#

DHA inspects. A facility that registers patients but does not transmit their clinical events — or transmits them with missing identity data — is non-compliant even if the clinic is doing good medicine. The software does the transmitting for you. Your job is narrower and very manageable: make sure the one-time setup is correct, make sure your team captures complete data, and review the daily violations log. Get those three right and NABIDH runs itself.

The whole job in three sentences#

#WhatWho owns it
1One-time setup — tenant authority code, each branch's DHA facility ID, each doctor's DHA (Sheryan) ID.Owner / Admin
2Complete data, every visit — patient identity (DOB + Emirates ID / passport), the medical record, the result, the discharge.Reception, Provider, Nurse, Lab
3Daily review — open the DHA / NABIDH violations log each morning and clear yesterday's gaps.Clinic Manager / Compliance Officer

What the software does for you, with no clicks#

Once setup is correct, the system builds and sends the right NABIDH message the moment a staff action happens — no "send to DHA" button, no separate data entry. A patient checked in → a registration message goes out. A lab result saved → a result message goes out. The encounter finishes → a discharge message goes out. See the complete message map for exactly which action sends what.

The one thing to understand about "silent" gaps#

NABIDH never guesses. If a required piece of identity is missing — no date of birth, no Emirates ID for a resident — the system refuses to send a fabricated record and instead logs a build failure. That is correct behaviour (a wrong record at DHA is worse than a missing one), but it means a missing field is a silent compliance gap unless someone reviews it. That is exactly what the daily violations log and the transmission log are for.

  1. One-time setup — do this once, correctly, and most problems never happen.
  2. The complete message map — what each action transmits.
  3. Responsibilities by role — each person's short checklist.
  4. Every scenario answered — the edge cases and how to handle them.
  5. The clinical workflow in detail — the encounter from check-in to discharge.
  6. Inspection readiness — for the compliance officer.